I recently had a vehicle in with a symptom that I thought would be an easy fix, only to have it take up several hours that I had not anticipated losing. Does this sound familiar? The 1996 Chevy Tahoe had a customer concern of “No low-beam headlamps.”

Circuit Interruptus

Tech to Tech

Subject: Low-beam headlamps inoperative
Vehicle Application: 1996 Chevy Tahoe
Essential Reading: Diagnostician
Author: Brian Manley

Technician network is key in solving circuit problem

Tech to Tech

  • Subject: Low-beam headlamps inoperative
  • Vehicle Application: 1996 Chevy Tahoe
  • Essential Reading: Diagnostician
  • Author: Brian Manley

Technician network is key in solving circuit problem

I recently had a vehicle in with a symptom that I thought would be an easy fix, only to have it take up several hours that I had not anticipated losing. Does this sound familiar?
The 1996 Chevy Tahoe had a customer concern of “No low-beam headlamps.”

“How hard could this one be?” I thought to myself. I started with the basics and confirmed that, yes, only the high-beam headlamps functioned. I performed a cursory inspection of the headlamp wiring to the bulbs, searching for any clues such as animal intrusion or substandard repairs. It all looked like it was original-equipment manufacturer and untouched, so I pulled the fuse cover and searched for the headlamp fuses. On this truck there was a 50-amp Maxifuse for headlamps in the underhood fuse/relay box, and a daytime-running-lamp fuse in the underdash fuse box. Both of these tested fine, so I performed my normal “running of the fuses” to ensure that I didn’t overlook a mislabeled blown fuse. I found no open fuses, so I went in search of information regarding the operation of the circuit and found no description on my aftermarket information system.

Next, I needed to pull up the wiring diagram to see all of the circuit components, which included headlamp and dimmer switches, two fuses, daytime-running-lamps relay, module and diode, fog-lamp switch and lamps, wiring, connections and lamps. In the world of copper wires and current flow, everyone is happy as long as there are no interruptions. That’s when we see the cars, when those electrons can no longer get to their designed destination, activating the circuit they were destined to complete.

I spent some time searching for the information needed, but – faced with a backlog of work to get done and a headache from either extended time inverted under the dash or a lack of calories, and since it was way past my lunch time – I decided to stop, grab some food and search iATN (International Automotive Technicians’ Network) for any more clues. I had gone there before, and I have had success searching the “Closed With Fix” section. Sure enough, after some sleuthing, I found a post by an iATN technician-sponsor from Pennsylvania named Bob Leonard, who had seen several of these trucks in his shop and had discovered his own pattern case failure.

Bob said in his post: “I’ve worked on three vehicles (all the same year, type and options as subject vehicle) that were found to have an overheated wire – to the point of discoloration and breaking – at the turn-signal combination switch. The wire is a tan wire coming from the headlight dimmer switch to the daytime-running-light relay and is powered up in the low-beam position.”

I immediately got a little excited as I dropped my sandwich, grabbed my flashlight and dove back under the dash. Sure enough, twisted around behind the loom and covered by lots of camouflage was a completely broken wire – right at the headlamp dimmer switch! I made a temporary connection and immediately had low-beam headlamps. I was happy to have found the root cause, but why was there discoloration and corrosion at the point of the broken wire, along with both adjacent wires? I’m used to seeing green, fuzzy contamination in exterior locations where exposure to the elements is a big issue, but under a nice, safe dashboard? I searched in vain for the reason for the corrosion but found none. In fact, Bob’s post was the only one that pointed to the root cause.

Bob also said: “I found that some of the prongs on the DRL relay showed discoloration from excessive heat. I checked the rest of the system for excessive voltage drops but could find nothing out of the ordinary … I replaced the DRL relay on all three trucks as a precaution but would feel better if I could find the root problem.” I checked my DRL relay for similar signs of overheating, but mine looked just fine. I also checked for excessive voltage drops or current flow in the affected circuit without any strange numbers.

In a similar case study, I recall finding inoperative headlamps on another popular domestic brand that had me scratching my head for a while. After tracing many circuits and isolating an open circuit in a feed wire to the bulbs, I found a wire that looked normal except for some “bulging” in a remote section, not at a connector. The bulge was hard, and when I cut the insulation there was corrosion sufficient to stop virtually all current flow at that point. The wire appeared undamaged until I got to it.

Did this wire “wick” moisture along its length to that point? Was the wire manufactured with a defect? I never got my answer, and this repair, just as the one with the Tahoe, reminds me that high-resistance circuits can happen even without any apparent outside trauma. How many open circuits or high-resistance repairs have you made that resemble these two case studies?

I am grateful to Bob for leading me to the root cause sooner than I would have gotten there by myself. This is a great case study that underscores how important technician networks can be for the professional-technician community.

Brian Manley is a vocational automotive instructor for the Cherry Creek school district in Aurora, Colo. He is an ASE master certified automobile technician and a former member of the National Automotive Technicians Education Foundation board of trustees. You can reach him at [email protected].

The copyrighted article featured above is reprinted with the permission of AutoInc., the official publication of the Automotive Service Association (ASA). To learn more about ASA and its commitment to independent automotive service and repair professionals, visit www.ASAshop.org or call (800) 272-7467.

You May Also Like

Shift of the shaft: Diagnosing Chrysler 48RE manual shaft issues

The TorqueFlite transmission has been around since mid-to-late 1950s. There have been many changes surrounding the manual shaft and rooster comb through the years. This transmission shaft controls the position of the manual valve that directs oil for the gear ranges, but it also is used for a Reverse light control as well as Park/Neutral

The TorqueFlite transmission has been around since mid-to-late 1950s. There have been many changes surrounding the manual shaft and rooster comb through the years. This transmission shaft controls the position of the manual valve that directs oil for the gear ranges, but it also is used for a Reverse light control as well as Park/Neutral safety control. As it evolved, changes to these safety backup switches caused extra stress against the rooster comb that posed new challenges to the technician. 

Sometimes, a diagnostic code is all you need

With ATSG having the opportunity to help shops solve problems, sometimes we get faced with some real doozies. A shop will call and give us a laundry list of DTCs, leaving us to think someone must have a bulkhead connector unplugged. We then go through the arduous task of deciding which codes prompted other codes

10L80 and 10R80 pump gear differences

You may have seen an article in the August 2023 issue of Transmission Digest called “GM 10L80: A new kind of pump noise,” which goes over how the front cover housing in the 10L80 is fitted with a converter drive gear and idler gear. The idler gear drives the pump’s driven gear, and is press

Shift Pointers: What to do when the 62TE TRS tab breaks

How frustrating it is when on a hot summer day, as you go to open a nice cold can of your drink of choice, and the tab breaks off? You are outside, away from any tools to remedy the problem quickly. It now requires a MacGyver mentality looking around at the resources available to get

Going the extra mile: Proving your transmission repair suspicions

A 2003 Honda Pilot with a five-speed three-shaft transmission came into our shop with a customer concern that the vehicle had no power, and the “D” light was flashing. I first did a scan for codes to see what it came up with, and the scan tool returned four DTCs: P1298 (ELD voltage high), P0135 (H02S

RRfeature-1400

Other Posts

Spotting different 68RFE designs through the years to avoid issues

The Chrysler 68RFE has had several changes through the years. Its four-speed predecessor began with a noisy solenoid pack identified by a black colored pass-through case connector (seen in Figure 1).  Related Articles – Outgrowing the walls: The story of EVT Transmission Parts – Valve body and component suppliers: A comprehensive list – Shift Pointers:

Shift Pointers: Failures caused by incorrect tire sizes

For years ATSG has produced a wide range of issues related to improper tire sizes on vehicles. Even under-inflated tires have been known to cause issues. Problems such as premature failure with an active 4WD transfer case will occur with incorrect tire sizes. Related Articles – Understanding lube flow control valves in Toyota/Lexus UA/UB80 transmissions

Shift-Pointers-Jan-Figure-1-1400
Understanding lube flow control valves in Toyota/Lexus UA/UB80 transmissions

The Toyota/Lexus UA80 and UB80 transmissions first came out in 2017 in Highlanders and Siennas. The UA80 is used in V6 applications, and the UB80 is paired with four-cylinder versions. They have been called Toyota New Global Architecture type transmissions, and alternately referred to as the “Direct Shift 8AT” eight-speed automatic transmission. This transmission was

Tasc-Tip-December-Figure-1---LFC-Valve-OE-Partial-Circuit-Diagram-1400
How reading through service bulletins can turn a technician into the customer’s hero

Over the last 28 years of being a technician, I have developed the habit of checking for and reading technical service bulletins at the forefront of the diagnostic process, especially when an unfamiliar vehicle exhibiting blatant or straightforward concerns comes into the shop. I have found many valuable nuggets of information while reading over these