Two Unique Situations, Two Happy Customers

All of our initial diagnostic evaluations include a battery and charging system test. I’ll bet you can guess the outcome of this one; the battery failed, but the alternator had passed. At this point we informed the customer that some electrical testing was going to be necessary in order for us to find out what was causing the problem. The customer agreed to that and we then proceeded with the job.

Two Unique Situations, Two Happy Customers

R&R Tech

Author: Carman Klaber
Subject Matter: U660E, A4BF1
Issue: Corrosion and wiring

R&R Tech

  • Author: Carman Klaber
  • Subject Matter: U660E, A4BF1
  • Issue: Corrosion and wiring

I wanted to share with you a couple of situations that I have run into over the past couple months. The first one is a 2010 Lexus RX350 that came in on the back of a tow truck. This SUV is equipped with a 3.5L V6 and a U660E transaxle. The customer had it towed because the vehicle was in failsafe mode. When I began the evaluation, the first thing I noticed was the strong odor of battery acid when I opened the hood (Figure 1). One look at the battery and I knew this was going to need to be addressed, but at this point I did not know what was causing the failsafe problem. When the scan tool was connected I discovered that I had no communication with the TCM, but did have communication with all of the other modules.

All of our initial diagnostic evaluations include a battery and charging system test. I’ll bet you can guess the outcome of this one; the battery failed, but the alternator had passed. At this point we informed the customer that some electrical testing was going to be necessary in order for us to find out what was causing the problem. The customer agreed to that and we then proceeded with the job.

I am sure that you guys have seen these vehicles in your shop and know that the battery is positioned directly above the transaxle, so knowing that and the fact that the battery had evidence of leaking acid, I knew where I was headed. The TCM is mounted directly on top of the unit and plugs straight into the transmission case connector. I started by checking power and grounds on the vehicle harness to the TCM and found everything in order. I disconnected the harness and everything looked good with no corrosion or pin-fit connection issues.

Next I removed the two bolts that hold the TCM to the case. The TCM just fell off onto the floor, and I was not expecting that! The case connector and the TCM were corroded so badly that four of the pins and the plastic housing were stuck in the TCM (figures 2 and 3). I think I found the problem! My next move was to recommend a pan inspection to see if there was any need to go inside the transmission, or just replace the internal harness and TCM. After dropping the pan it looked good inside, no clutch material or excessive metal. I then recommended replacing the internal harness, TCM and battery; I also recommended a transmission fluid flush.

The parts were a couple of days out, so while I was playing the waiting game I cleaned the area as best I could and installed the new battery. When the parts arrived I pulled the valve body down and replaced the internal harness, installed the TCM, and flushed the transmission fluid. The TCM came already loaded with the calibration so all I needed to do was the initialization procedure, “reset memory” as Toyota/Lexus call it and go for a road test. The transmission shifted as it should and I couldn’t be more pleased. The customer was also pretty happy that they did not need to replace the transmission.

The next vehicle I wanted to discuss had an issue that you will not see that often. The car was a 2006 Hyundai Tiburon with a 2.0L 4-cylinder with an A4BF1 transmission. While going through the initial evaluation and connecting the scan tool, it had a DTC stored for P0711 TFT signal abnormal, but no other codes. The customer concern was that everything seemed to work fine but the CEL light would “come and go.”

With the scanner attached and the transmission data PIDs on the screen, I could see that the transmission temperature was 45º F, which was fairly close to the ambient temperature at the time. That, coupled with the customer concern, I was expecting an intermittent issue. As I took off on the road test the transmission shifted well but the TFT PID never went above 45ºF, so therefore the TCC never engaged. This appeared to be what was causing the code to set, so I needed to find the root cause of the issue. After returning to the shop and pulling onto the lift, I started taking a closer look in the area of the transmission and noticed an extra red wire in the loom to the mass air flow sensor, as seen in the photo (Figure 4).

After peeling the tape and wiring loom off the red wire, I could see that it was spliced into the yellow/black wire in cavity #5 of the MAF sensor pigtail. The other end of the wire was spliced into the gray wire cavity #1 of the transmission case connector, which is for the TFT sensor (Figure 5).

I talked to a couple of colleagues about this but they had never seen nor heard of this scenario. I even tried the tech support search, but nothing came up. My theory is they were trying to trick the ECM into thinking it was running cold so it would enrich the fuel mixture and supposedly get better power and performance. I just could not figure out why we went to the transmission temp sensor. Maybe they were trying to have the IAT temp and transmission temp match? I wish I knew what went through some of these people’s thought processes.

After returning everything back to a factory configuration, I serviced the transmission and went for another road test. Watching the scanner, the TFT sensor was rising as it should, and when it was warm enough the TCC would now engage as it was designed to. We called and let the customer know his car now worked like it should have and he was happy that the source of the intermittent CEL was solved. Both cases could have turned out worse for the customers, but a happy customer means repeat business.

You May Also Like

Dealing with the increasingly common pin-fit problem

I want to talk a little bit about a common diagnostic misstep or overlooked problem that is prevalent in the automotive repair industry and seems to be on the rise. Pin-fit or tension can deal us a fit sometimes (pun intended), especially if we do not have the proper tools to determine if this mode

RR-Tech-September-FIG-1-1400

I want to talk a little bit about a common diagnostic misstep or overlooked problem that is prevalent in the automotive repair industry and seems to be on the rise. Pin-fit or tension can deal us a fit sometimes (pun intended), especially if we do not have the proper tools to determine if this mode of failure might be the cause. I have a couple of case studies to share that I have seen recently, and will share some testing protocols that I have used over the years to attempt to correctly diagnose a related issue or a code. 

Watch: Replacing a transmission and components

Dave Hritsko and the team have already removed a full transmission in a previous video. This time, see an in-depth explanation of the parts, components, and steps in how they make the upgrade with a remanufactured transmission along with new aftermarket components with the help of students from Ohio Technical College. Related Articles – Can

Removing-a-Transmission-with-Dave-from-Transtar-1400
Watch: How to remove a transmission

Watch Dave Hritsko from Transtar and team members from Ohio Technical College as they remove an old transmission and replace it with a newly remanufactured transmission. Related Articles – Road to AAPEX season 2, ep. 9: The roads that connect us – Watch: CVT modules and programming – Watch: CVT fluid diagnostics

Back to square one: When a transmission replacement doesn’t fix the problem

The subject of this article is a 2002 Ford Ranger with a 3.0L V6 engine and 5R44E transmission. There were 191,622 miles on the vehicle when it arrived at our shop. The owner said that the transmission was not shifting correctly and the OD lamp was flashing. Related Articles – Ford 8F35 maintenance tips: Planetary failure

RRfeature-1400
The technician’s duty to the customer

I want to talk about some of the recent trends of particular cars and trucks that we see showing up at repair shops for work to be done. It seems to be a perfect storm of high used car prices, lack of new car inventory, and a bit of economic uncertainty that brings us to

rr-feature-1400

Other Posts

Diving into electrical testing and wiring with the 948TE

We had a 2014 Jeep Cherokee come into our Bellevue, Neb. facility with a transmission that would not shift. This all-wheel drive vehicle was equipped with a 3.2L engine and a 948TE nine-speed transmission. Related Articles – Sometimes, a diagnostic code is all you need – 10L80 and 10R80 pump gear differences – Top 20

RR-Tech-June-FIG-1-1400
Potential causes of an overheated transmission: It’s not always what you think

If a transmission starts overheating, the root cause must be something to do with the transmission itself, right? Not always. The following are a few examples where the transmission was not to blame. Related Articles – Performance supplier listings 2024 – Shift Pointers: What to do when the 62TE TRS tab breaks – Diagnosing Ford

A mysterious shudder: Locating a problem with no fault codes

It was a dark stormy night… well, not really; it was just an ordinary Tuesday. Related Articles – Jatco JF613E transmission quick reference material – Complete the 2024 transmission shop survey for a chance to win a gift card – Think pink: Curtis Price strikes out on his own and has Liberty Transmission and Auto

RRfeature-April-23
TCM trouble and the importance of being certain about parts replacement

It’s a tale as old as time. A vehicle comes in and, despite having been recently repaired by another shop, the vehicle owner’s concern is still present. In the case of this story, the vehicle came from a local shop we work closely with. The truck in question is a 66,000-mile 2006 Chevrolet Silverado 2500

RR-Tech-March-FIG-1-1400