‘Test, Don’t Guess’ When Lightning Strikes - Transmission Digest

‘Test, Don’t Guess’ When Lightning Strikes

I have had the opportunity to deal with several vehicles that were actually struck by lightning. Usually, various modules are fried; however, there was one that just threw me for a complete loop. The vehicle ran, but no electrical circuits in the body worked (windows, door locks, radio, etc.) I expected to find a main power circuit problem, but much to my dismay, there wasn’t a single blown fuse. The problem turned out to be on the ground side of the vehicle. The main body ground circuits that ran along the rocker panel under the driver-side doorsill were completely melted away.

Tech To Tech

  • Author: Jeff Back
  • Subject Matter: Lightning Strikes
  • Vehicle Application: Various
  • Issue: Tracing problems following lightning strike

It’s your best approach to tracking down the problem(s).

Problem description: Check electrical system. The battery goes dead after sitting a couple of days.

“Oh, yeah,” the customer said, “there was a lightning strike in the parking lot where I work that might have affected the van.”

Most of the time, when I get in a vehicle that has a problem associated with a lightning strike, it’s due to an insurance company adjuster trying to determine the validity of the claim.

I have had the opportunity to deal with several vehicles that were actually struck by lightning. Usually, various modules are fried; however, there was one that just threw me for a complete loop. The vehicle ran, but no electrical circuits in the body worked (windows, door locks, radio, etc.) I expected to find a main power circuit problem, but much to my dismay, there wasn’t a single blown fuse. The problem turned out to be on the ground side of the vehicle. The main body ground circuits that ran along the rocker panel under the driver-side doorsill were completely melted away.

This particular vehicle only had liability insurance, although the owner did say that four other vehicles in the parking lot had problems and all four were totaled by their insurance companies. “But,” he said, “they were closer to where it hit.” I informed my customer that if his vehicle did manage to become part of the lightning strike incident, that multiple modules may be involved and an accurate estimate would be difficult to obtain until after some investigation. The customer was fine with that and said to proceed step by step.

I started my drain tracing as I usually do by checking to make sure that none of the body input signals, such as the door handle and closure switches, were active – in other words, anything that would keep the body control awake. Getting a new Body Control Module (BCM) for a bad switch input is a mistake I see made often in our line of work. Something as simple as having the key in the ignition will cause an input that keeps that BCM awake.

Whenever possible I like to wait an hour before beginning a draw test with the vehicle properly at rest and with the hood open ahead of time. Next, I use a current probe – in this case, attached to my voltmeter set on the Milliamp (mA) scale. The probe I use outputs a voltage signal that is directly proportionate to the current it sees when set on the low scale. This one was showing more than 700mA (Figure 1).

This is well over the accepted at-rest current. In fact, for this model I typically see less than 30mA of at-rest current.

The next step was to find out where the excess current was going. I started this quest by eliminating one of the often overlooked but not uncommon causes: the alternator. By simply grasping the alternator’s feed and output circuits in the jaws of the probe, it was quickly eliminated as a suspect and I was able to move to the power distribution box (PDC) feed. This PDC had a quick release that allowed me to lift it up from the battery box for full access to its feed and output circuits. I measured the full current draw on the main feed (Figure 2).

I could then measure the voltage drop across each of the PDC’s fuses to see which circuits were carrying current. So far I hadn’t had to break any circuits to do my testing and risk waking any modules. By using the voltmeter’s millivolt (mV) scale I got a reading on two fuses.

Next, I went back to the current probe and read the current on the circuits leaving those two fuses under the fuse box and saw that one of them was carrying most of the current. By using the wiring diagram, I was able to see that it was the BCM carrying the current. With no discernible inputs, I made the determination that the module was the culprit. Before replacing the module, I printed out the connector views and pin-checked each circuit to make sure I hadn’t overlooked any circuits that I couldn’t parameter check.

“Test – don’t guess” has always been my motto. I like to think I have done all I can before replacing a nonreturnable module. I hate finding myself in the unenviable position of explaining to the customer the next “other necessary thing” that has to be done to fix the vehicle. I realize that sometimes it takes fixing one problem before finding another, but I’m not a big believer in the “chain reaction” theory that some use to explain all the parts they needed to replace to fix one problem.

The new BCM took care of the drain issue. I then was able to get 27 mA of “at-rest” current. I took the vehicle down the road for a test drive and discovered that the transmission was running in limp mode and the shift indicator lights were boxed and blinking. The scan tool showed no data coming from the transmission control module.

So the question became: “How many more modules are going to be a problem and how do I get to a bottom-line estimate?”

The best way to proceed from there, in my opinion, was to make the customer aware of the possibility that there other modules may have been involved and I needed basically an open-ended authorization to continue.

After getting more time authorized to do further testing, I printed out the wiring diagram for the transmission control module (TCM) and the connector view.

The TCM showed a P 1684 code, which just says the TCM has been disconnected. I figured I set that when I removed the connector to get the pin cover off.

I did the power and ground test and got 12 volts on the battery circuit and good grounds.

Next, I checked the trans solenoid control circuits and couldn’t get any voltage on any of the solenoid circuits. I tested the transmission controls relay control circuit and couldn’t get any voltage there either. After back-tracing the control circuit, I discovered that the integrated power module (IPM) had an open in the circuit between the trans relay control circuit and the circuit from the TCM.

Since the PRND31 indicator was showing boxes around the letters, I continued measuring the voltages and comparing them to the diagram in the diagnostic chart. The numbers didn’t agree with the chart and the data voltage seemed odd, with three of the four data switch circuits at 3.5 and the fourth one reading 7.4 volts.

The vehicle still started but ran with the transmission in limp mode. The park neutral start switch is separate from the PRNDL switch.

This made three more components look to be possible victims of the high voltage from the lightning strike.

The customer was very cooperative in giving the authorization for the repairs and was thankful that we were even willing to work on the problem. I found out later that the customer had been to several places and had difficulty getting anyone willing to diagnose a lightning strike-related problem.

Jeff Bach is the owner of CRT Auto Electronics in Batavia, Ohio. He can be reached at [email protected].

This copyrighted article is reprinted with the permission of AutoInc., the official publication of the Automotive Service Association (ASA). To learn more about ASA and its commitment to independent automotive-service and repair professionals, visit www.ASAshop.org or call 800-272-7467.

You May Also Like

Sometimes, a diagnostic code is all you need

With ATSG having the opportunity to help shops solve problems, sometimes we get faced with some real doozies. A shop will call and give us a laundry list of DTCs, leaving us to think someone must have a bulkhead connector unplugged. We then go through the arduous task of deciding which codes prompted other codes

With ATSG having the opportunity to help shops solve problems, sometimes we get faced with some real doozies. A shop will call and give us a laundry list of DTCs, leaving us to think someone must have a bulkhead connector unplugged. We then go through the arduous task of deciding which codes prompted other codes to set—we’re actually diagnosing diagnostic codes themselves at that point. So, when an issue comes up on our help line with codes that actually tell the story, it makes for a nice change, as well as a quick pathway to a repaired vehicle.

10L80 and 10R80 pump gear differences

You may have seen an article in the August 2023 issue of Transmission Digest called “GM 10L80: A new kind of pump noise,” which goes over how the front cover housing in the 10L80 is fitted with a converter drive gear and idler gear. The idler gear drives the pump’s driven gear, and is press

Shift Pointers: What to do when the 62TE TRS tab breaks

How frustrating it is when on a hot summer day, as you go to open a nice cold can of your drink of choice, and the tab breaks off? You are outside, away from any tools to remedy the problem quickly. It now requires a MacGyver mentality looking around at the resources available to get

Going the extra mile: Proving your transmission repair suspicions

A 2003 Honda Pilot with a five-speed three-shaft transmission came into our shop with a customer concern that the vehicle had no power, and the “D” light was flashing. I first did a scan for codes to see what it came up with, and the scan tool returned four DTCs: P1298 (ELD voltage high), P0135 (H02S

RRfeature-1400
Diagnosing Ford 10R60, 10R80 and 10R140 series speed sensor issues

Ford 10-speed 10R series transmissions utilize four two-wire, Hall-effect sensors — TSS, ISSA2, ISSAB and OSS — for providing speed signals to PCM or TCM. They are supplied nine volts by a PCM or TCM and assist in the control of clutch apply/release timing that is used in determining shift quality, including TCC. Related Articles

Other Posts

Shift Pointers: Failures caused by incorrect tire sizes

For years ATSG has produced a wide range of issues related to improper tire sizes on vehicles. Even under-inflated tires have been known to cause issues. Problems such as premature failure with an active 4WD transfer case will occur with incorrect tire sizes. Related Articles – Valve body and component suppliers: A comprehensive list –

Shift-Pointers-Jan-Figure-1-1400
Understanding lube flow control valves in Toyota/Lexus UA/UB80 transmissions

The Toyota/Lexus UA80 and UB80 transmissions first came out in 2017 in Highlanders and Siennas. The UA80 is used in V6 applications, and the UB80 is paired with four-cylinder versions. They have been called Toyota New Global Architecture type transmissions, and alternately referred to as the “Direct Shift 8AT” eight-speed automatic transmission. This transmission was

Tasc-Tip-December-Figure-1---LFC-Valve-OE-Partial-Circuit-Diagram-1400
How reading through service bulletins can turn a technician into the customer’s hero

Over the last 28 years of being a technician, I have developed the habit of checking for and reading technical service bulletins at the forefront of the diagnostic process, especially when an unfamiliar vehicle exhibiting blatant or straightforward concerns comes into the shop. I have found many valuable nuggets of information while reading over these

Sometimes, you should sweat the small stuff

It’s a common phrase: There may have been a time when you worried about something, and someone who knew what you are going through said, “Hey, don’t sweat the small stuff.” Sometimes, this may be good advice. But other times, it may be wise to handle the small stuff before it becomes bigger “stuff.”  Related